Article Text
Abstract
A 79-year-old man with a history of bioprosthetic aortic valve (AV) replacement in 2008 and atrial fibrillation was admitted with acute pulmonary oedema. Transthoracic and transoesophageal echocardiograms revealed significantly elevated AV gradients and thickened AV leaflets. These findings were suggestive of bioprosthetic valve thrombosis (BVT). The patient was treated with intravenous heparin and commenced on vitamin K antagonist. BVT remains an under recognised cause of late prosthetic valve dysfunction. A lack of awareness of BVT occurring beyond 3 months post-implantation is likely to account for this. Furthermore, structural valve degeneration is the most common mechanism of late prosthetic valve dysfunction. Recognising the difference between the two aetiologies is crucial as the management plan differs significantly. Here, we report a case of very late bioprosthetic AV thrombosis diagnosed 8 years after implantation. This was successfully treated with systemic anticoagulation, thereby avoiding the need for redo cardiac surgery.
- Heart failure
- Valvar diseases
Statistics from Altmetric.com
Footnotes
Contributors KB, GK and BH were all involved in the care of this patient. KB was involved in the manuscript preparation and acquired patient consent. GK and BH supported KB in reviewing the draft and adapting it to the journal’s requirement.
Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.
Competing interests None declared.
Provenance and peer review Not commissioned; externaly peer reviewed.
Patient consent for publication Obtained.